WincoTek 400G QSFP112 DR4 500 m Transceiver(WTQ112400-DR4-500C)
WTQ112400-DR4-500C is a 400G QSFP112 DR4 transceiver for single-mode links up to 500 m. Four 106.25 Gb/s electrical lanes map straight onto four 53.125 GBd PAM4 optical lanes at 1310 nm, on an MPO-12 APC connector. It is built as a silicon photonics design with a DSP inside, and serves 400G Ethernet in data center and cloud networks.

400G QSFP112 DR4 at a glance.
Main optical, electrical and environmental values for WTQ112400-DR4-500C.
| Parameter | Value |
|---|---|
| Ordering code | WTQ112400-DR4-500C: 425 Gb/s, 1310 nm, 500 m, SMF, DDM, MPO 1×12 APC, 0 to 70 °C |
| Data rate | 425 Gb/s; 4 × 106.25 Gb/s electrical interface; 4 × 53.125 GBd PAM4 optical lanes |
| Application | 400G Ethernet; data center and cloud networks |
| Wavelength | 1304.5 to 1317.5 nm, each lane |
| TX power, each lane (avg.) | −2.9 to 4 dBm; OMAouter −0.8 to 4.2 dBm |
| RX sensitivity (OMAouter), each lane | −4.4 dBm; stressed sensitivity −1.9 dBm |
| RX average receive power, each lane | −5.9 to 4 dBm; damage threshold +5 dBm |
| Reach / FEC | Up to 500 m on single-mode fiber; FEC required on the host |
| Connector | MPO-12 (APC) |
| Power | <12 W |
| Supply | 3.135 to 3.45 V |
| Case temperature | 0 to 70 °C |
| DDM | Yes |
| Environmental | RoHS compliant |
Main values for WTQ112400-DR4-500C. Full WincoTek datasheet: DatasheetPDF
Where it is used.
From the datasheet application list and common network use.
- 400G Ethernet switch-to-switch links up to 500 m
- Leaf-spine fabrics built on 112G-SerDes switches with QSFP112 ports
- Data center and cloud network interconnects on parallel single-mode fiber
QSFP112 or QSFP-DD?
Same 400G DR4 optics, different host interface.
QSFP112 carries 400G on four electrical lanes of about 100G each, so it fits switches whose ports run 112G SerDes. A QSFP-DD 400G module uses eight 50G lanes in a double-row connector. Check the host port type first: the optical side of both DR4 types is the same four 1310 nm lanes on MPO-12.
The datasheet states that FEC on the host is required to reach 500 m. Enable it on both ends before testing the link.
Use single-mode MPO-12 trunks with APC end-faces. A flat PC connector does not mate correctly with an APC receptacle.
Related WincoTek models.
400G DR4-class options by host form factor. For one duplex LC pair instead of parallel fiber, see FR4.
| Model | Form factor | Reach | Optics | Connector | Max. power |
|---|---|---|---|---|---|
| WTQ112400-DR4-500C this page DatasheetPDF | QSFP112 | 500 m | 4 parallel lanes, 1310 nm | MPO-12 (APC) | <12 W |
| WTQD400-DR4 DatasheetPDF | QSFP-DD | 500 m | 4 parallel lanes | MPO-12 (APC) | 8 W (datasheet target) |
| WTOS400-DR4-500C-CM DatasheetPDF | OSFP | 500 m | 1310 nm | MPO-12 (APC) | <10 W |
| WTQD400-DR4-10 DatasheetPDF | QSFP-DD | 10 km | 4 parallel lanes (4×LR1) | MPO-12 (APC) | <8 W |
| WTQD400-FR4 DatasheetPDF | QSFP-DD | 2 km | 4 lanes at 1310 nm | Duplex LC | <12 W |
Full range and all datasheets: optical transceivers. Guide: 400G DR4 vs FR4 vs LR4: which to choose.
Coded to your host, tested first.
Host vendor names describe the target platform only.
Coding & compatibility
WTQ112400-DR4-500C is coded for the host platform you name, for example Cisco, Juniper, Huawei, Arista, Nokia switches and routers. We read and back up the module data, write the approved profile, then read back and verify it with DDM. Compatibility is validated per host model and software release, so we recommend testing coded samples on your equipment before a volume order.
Quality & warranty
Built in ISO 9001-certified manufacturing partners. CE, RoHS, FCC and TÜV test reports are available for each model on request.
Warranty: hardware 3 years, software 1 year.
Questions on this model.
Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.
What host port does WTQ112400-DR4-500C need?
A QSFP112 port. The module uses a 4 × 106.25 Gb/s electrical interface, so it is meant for hosts with 112G-class SerDes.
Is FEC required?
Yes. The datasheet notes that FEC on the host system is required to support the maximum 500 m distance.
Which fiber and connector does it use?
Single-mode fiber with an MPO-12 connector with APC end-face. The four lanes run at 1304.5 to 1317.5 nm.
How is it different from the QSFP-DD DR4?
The optics are the same class: four 1310 nm PAM4 lanes up to 500 m on MPO-12 APC. WTQD400-DR4 plugs into QSFP-DD ports with an eight-lane 400GAUI-8 interface; WTQ112400-DR4-500C plugs into QSFP112 ports with four 106.25 Gb/s lanes.
Can WTQ112400-DR4-500C be coded for our switches?
Yes. WTQ112400-DR4-500C is coded for the host platform you name, then read back and verified. Compatibility is validated per host model and software release, so test coded samples before a volume order.
Request a quote for WTQ112400-DR4-500C.
Send the host model and software release, quantity and coding needs. We reply with a matched P/N and sample plan.
Email waley@wincoteknetwork.com · WhatsApp / phone +86 176 8896 6828
Optical network solutions