Metro, backboneand DCI transport,10G to 800G per wave.

Modular WDM and OTN platforms, muxponders and optical-layer cards for operators, ISPs, data centers and private networks. Each design starts from your route, span loss and service mix, and is validated before cutover.

WincoTek 5U DWDM/OTN transmission chassis
Per fiber
25.6 Tb/s
Channels
96 @ 50 GHz
Per wave
Up to 800G
Protection
<50 ms
Platforms

From a 1U DCI box to a 16-slot chassis.

The WTN8600-DCI series puts electrical and optical layers in one compact unit for data center interconnect. The WTNS8600 family covers CWDM and DWDM transport from 1.25G to 400G per channel, with open line systems and integrated point-to-point devices.

DCI / OTN · 2U

WTN8600-DCI8

Optoelectronic integrated WDM platform for data center interconnect. Hot-pluggable modular cards, front-to-rear airflow and a 600 mm cabinet depth, so it installs alongside IT equipment. Single-wave capacity up to 400G, with 9-degree ROADM and FlexGrid.

Per subrack
3.2 Tb/s
Per fiber pair
25.6 Tb/s
Line rate
100G–400G
Modulation
QPSK / 8QAM / 16QAM
Grid
96λ @ 50 GHz
Frequency
191.35–196.1 THz
Protection
OLP / OMSP / OCHP
Management
SNMP, NETCONF / YANG

Platform range

PlatformType / size (H × W × D)Slots / channelsCapacityPower and notes
WTN8600-DCI8DCI / OTN, 2U
88 × 446 × 450 mm
8 service slots3.2 Tb/s per subrack; 25.6 Tb/s per fiber pair (C+ band, 400G × 64λ)Typical <800 W; 2+1 fans; 1+1 CRPS AC / 240 V HVDC / −48 V DC
WTN8600-DCI4DCI / OTN, 1U
44 × 444 × 490 mm
4 service slots1.6 Tb/s per subrack; 25.6 Tb/s per fiber pairTypical <550 W; 1+1 fans; 1+1 CRPS
WTNS8600 IBWDM chassis, 1U
44 × 442 × 280 mm
4 slots, rear powerUp to 400G per channel; CWDM 18 / DWDM 96 waves (50 GHz)120 W max
WTNS8600 IFWDM chassis, 1U
44 × 442 × 220 mm
4 slots, front powerUp to 400G per channel50 W max
WTNS8600 IIWDM chassis, 2U
88 × 442 × 220 mm
8 slotsUp to 400G per channel160 W max
WTNS8600 VWDM chassis, 5U
220 × 442 × 220 mm
16 slotsUp to 400G per channel450 W max
WTNS8600-OLSOpen line system, 1U
44 × 440 × 600 mm
48 channels, 100 GHz, C-bandNRZ 1–32G, PAM4 40G / 100G, coherent QPSK / 8QAM / 16QAMIntegrates Mux / Demux, OA, OTDR, OCM, OLP, OSC and TDC
WTNS8600P 100GIntegrated WDM, 1U
44 × 442 × 600 mm
Up to 12 × 100G1.2 Tb/s per device; 2.4 Tb/s per fiber with two stacked unitsPlug-and-play point-to-point; 1+1 line protection
WTNS8600P 10GIntegrated WDM, 1U
Dimensions on request
Up to 48 × 10G480 Gb/s per device; 960 Gb/s per fiber stackedFE / GE / 10GE services; 1+1 line protection

WTNS8600 chassis: line rates 1.25G to 400G; STM-N, OTU-1/2/3/4, FE to 100GE, FC 1G–32G, EPON, GPON, CPRI and eCPRI services; point-to-point, chain, ring and mesh topologies; IEEE 1588v2 pass-through.

Electrical layer · Muxponders

10G to 800G service cards.

Muxponders map client services into OTN and onto a tunable DWDM wavelength. Coherent CFP2, QSFP-DD and OSFP DCO line optics cover metro, long-haul and DCI distances; all support ITU-T G.709 framing, performance monitoring and telemetry.

WincoTek P624 2x400G muxponder card with CFP2 line ports
WincoTek WTN8600-DCI4 1U DCI platform with P616, P524 and P514 cards
CardRateClient sideLine sideMappingServicesApplicationSlots
P716800G6× QSFP28 + 2× QSFP-DD / QSFP281× OSFP 800G DCO; 191.275–196.125 THz, Flex-Grid8× 100GE or 2× 400GE ↔ 1× 800G100GE, 400GE32 channels over 480 km (800G 16QAM)2
P6242× 400G8× QSFP282× CFP2-DCO 400G; 100G–400G adjustable8× 100G → 2× OTUC4100GE, 100GE FlexE, OTU4Metro and long-haul up to 600 km2
P616400G1× QSFP-DD / QSFP28 + 3× QSFP281× CFP2-DCO 400G; 100G–400G adjustable1× 400G or 4× 100G → 1× OTUC4100GE, 100GE FlexE, 400GE, OTU4Up to 600 km1
P614400G4× QSFP281× QSFP-DD DCO 400G; 100G / 200G / 400G4× 100G → 1× OTUC4100GE, 100GE FlexEUp to 450 km1
P5242× 200G4× QSFP282× CFP2-DCO; 100G / 200G4× 100G → 2× OTUC2100GE, 100GE FlexE, OTU4Up to 1,000 km1
P514200G2× QSFP28 + 10× SFP+1× CFP2-DCO2× 100G or 1× 100G + 10× 10G → 1× OTUC210GE, 100GE, FlexE, STM-64, 10GE WAN, FC800 / 1600 / 3200, OTU2 / 2e / 4Up to 1,000 km2
P512200G20× SFP+CFP2-DCO; 100G / 200G20× 10G → 1× OTUC210GE, STM-64, 10GE WAN, FC800, FC1600, OTU2, OTU2eUp to 1,000 km2
P422100G20× SFP+2× QSFP28 / QSFP-DD; grey or DCO coherent20× 10G → 2× OTU4, or 10× 10G → 1× OTU4 with line-side 1+110GE, STM-64, 10GE WAN, FC800, FC1600, OTU2, OTU2eUp to 1,500 km2

Line-side wavelength tunable across 191.35–196.1 THz on the 100G–400G cards. Single-fiber bidirectional transmission optional on P624, P616, P524, P514 and P512. Reach is a design figure; every link is engineered to its measured loss and OSNR.

Optical layer

Amplify, add, drop, protect, monitor.

Optical-layer cards integrate EDFA, WSS, VOA, OSC, OTDR, OCM and OLP functions to cut internal fiber patching. Amplifiers handle up to 48 channels at 100 GHz or 96 channels at 50 GHz in the C-band.

WincoTek OTA optical terminal amplifier card

Amplifiers

OA, OTA and OLA cards with EDFA for terminal and line stations.

WincoTek WSS 9-degree ROADM card

ROADM and OADM

9-degree WSS ROADM, plus TFF and SBM fixed OADM for dual or single fiber.

WincoTek MUX96 96-channel passive Mux/Demux rack

Mux / Demux

MUX48 and MUX96 athermal racks, managed through the DCI platform.

WincoTek OLP optical line protection card

Protection and monitoring

OLP 1+1 protection, OCM channel monitoring and 8-port online OTDR.

CardFunctionKey specifications
OAOptical amplifier1 slot. One or two EDFA (BA, PA or LA); optional OSC at 1510 nm, 1.25 Gb/s; VOA 0–15 dB. Gain options 14–20, 22–28 or 27–33 dB; output ≥20 dBm; noise figure <5.5 dB.
OTATerminal station amplifier2 slots. Built-in BA + PA, unidirectional OSC and VOA; BA gain 8–18 dB, PA 15–25 or 22–35 dB; output ≥21 dBm; AGC or APC; APR.
OLALine station amplifier2 slots. Two LA with east and west OSC; gain 15–25 or 22–35 dB; output ≥21 dBm; OCM and OTDR monitoring ports.
TFFDual-fiber fixed OADM1 slot. 4 or 8 channels at 100 GHz (191.4–196.1 THz); insertion loss ≤2 / ≤3 dB; adjacent isolation >25 dB; cascadable through the EXP port.
SBMSingle-fiber fixed OADM1 slot. 4 or 8 channels at 100 GHz, used in pairs; OSC at 1491 / 1511 nm; supports EDFA in series for single-fiber long-distance links.
MUX4848-channel Mux / Demux1U rack. 48 channels at 100 GHz; channel insertion loss ≤5.5 dB; athermal silicon waveguide grating; RJ-45 link to the WTN8600-DCI8 for inventory and status.
MUX9696-channel Mux / Demux2U rack. 96 channels at 50 GHz; channel insertion loss ≤6.5 dB; adjacent isolation ≥25 dB; managed through the WTN8600-DCI8.
WSS9-degree ROADM2 slots. Twin 1×9 WSS with BA, PA and OSC; 96 channels at 50 GHz; FlexGrid in N × 3.125 GHz; per-channel attenuation 0–15 dB in 0.1 dB steps; reconfiguration ≤3 s.
OLPOptical line protection1 slot. 1+1 line (OLP), multiplex-section (OMSP) or channel (OCHP) protection; switching <5 ms; input −25 to +21 dBm; switching unaffected by SCU failure.
OCMOptical channel monitor1 slot. 8 test ports; 1528.57–1567.34 nm; 50 / 100 GHz and FlexGrid; wavelength accuracy ±0.1 nm; scan time ≤1 s.
OTDROnline fiber monitoring1 slot. 8 test ports; 1625 nm; dynamic range ≥30 dB; detection distance ≥80 km; event dead zone <10 m.
Passive WDM

CWDM, DWDM and AWG, ready to splice.

Passive multiplexers and add-drop filters for fiber-saving links and system builds, in steel-tube, box and 19-inch rack packages. Channel plans follow the ITU-T grid.

ProductTechnologyChannelsChannel insertion lossPackages
CWDM Mux / DemuxThin-film filter, 20 nm spacing, 1270–1610 nm1 to 18≤0.8 dB (1 ch) to ≤5.0 dB (18 ch)Steel tube, ABS box, LGX box, 1U 19″ rack
CWDM OADMThin-film filter, 20 nm spacing1 to 16≤0.8 dB to ≤4.5 dBABS box, LGX box, 1U 19″ rack
DWDM Mux / DemuxThin-film filter, 100 GHz, 1525–1565 nm1 to 16≤0.8 dB to ≤4.5 dBSteel tube, ABS box, LGX box, 1U 19″ rack
DWDM OADMThin-film filter, 100 GHz1 to 16≤0.8 dB to ≤4.5 dBABS box, LGX box, 1U 19″ rack
AAWG heatless AWGSilicon waveguide grating; no power, software or temperature control40 / 48 (100 GHz), 80 / 96 (50 GHz)≤4.5 to ≤6.5 dB; flat-top or GaussianABS box, 1U 19″ rack

Also available: C-band red / blue band filters, fixed and tunable dispersion compensation (DCM, TDCM), and EDFA, SOA, OEO and Raman amplifier subsystems. Specifications per datasheet at quotation.

Featured systems

Three systems for three kinds of link.

Short fiber-constrained links, long-haul 800G and protected point-to-point DCI, each built from the same platform and card family.

O-band 100G DWDM · ColorS100

12 × 100G where fiber is short and scarce.

A compact, cost-efficient way to add high-capacity 100G channels where fiber is constrained and reach is short. Direct-pluggable 100G QSFP28 O-band LR1 client optics; passive up to 10 km, SOA-amplified to 30 km. ColorS100 runs the same architecture over a single fiber, bidirectionally.

Campus and building interconnect · metro short-reach links · mobile fronthaul and aggregation · 100G aggregation / 400G breakout · OLT uplink and backhaul.

Capacity
Up to 1.2T
Channels
4 / 8 / 12
Passive reach
10 km SMF
SOA reach
30 km SMF
Wavelength plan
1300.05–1312.58 nm
Client optics
100G QSFP28 LR1
Fiber
Dual or single
Power control
VOA
800G per wave

800G: 32 waves over 480 km

The P716 muxponder maps 8× 100GE or 2× 400GE onto one 800G wavelength through an OSFP DCO module. With 800G 16QAM, 32 channels reach 480 km; down-converted to 400G (QPSK at 150 GHz, 8QAM at 100 GHz, 16QAM at 75 GHz), 32, 48 or 64 waves run beyond 1,000 km.

0–60 kmFlexible ROADM or Mux / Demux, no amplifier
60–120 kmAdd OA at both ends
480 kmOA plus OLA line sites
  • Optical layer: 22-degree and 9-degree ROADM, 32-wave extended C-band and 40-wave ultra-wide C-band Mux at 150 GHz, Raman amplification, single-channel protection, 8-fiber OTDR, OCM.
  • P716: 2 slots, typical <120 W.
Protected DCI

400G DCI with route protection

A lightweight 2U DCI for point-to-point links: one coherent 400G wavelength carries 4× 100GE, with 1+1 optical line protection across two diverse routes and a 4-channel DWDM layer held for growth. Designed around 32 dB fiber attenuation per route.

  • Per site: 400G muxponder, 4-channel Mux / Demux, 1+1 OLP, two dual BA / PA amplifiers.
  • Monitoring: 8-port OTDR and browser-based EMS.
  • Growth: 3 channels not assigned to 400G traffic; spare slots at both sites.
See the reference design →
Protection & management

Carrier-grade protection, open management.

Network-level and device-level protection on every platform, managed through standard open interfaces and one browser-based system.

Protection

  • Optical layer: line 1+1 (OLP), multiplex section 1+1 (OMSP), channel 1+1 (OCHP).
  • Line side: port 1+1 on P422.
  • Device: main controller 1+1, CRPS power 1+1, redundant fans.
  • Performance: protection reversal delay <50 ms on the WTN8600-DCI series; OLP optical switching <5 ms.

Management

  • Interfaces: CLI, Web LCT, SNMP, NETCONF / YANG.
  • NMS: GUI management platform on browser / server architecture.
  • DCN: communication over the optical supervisory channel (OSC).
  • Visibility: service, OTN and optical-layer performance monitoring; telemetry; remote online upgrade.
Projects

Backbones, metro rings and private networks.

Optical transport references from WincoTek project records. Customer names are not published.

National ISP · Optical backbone
4×100G 500 km

Added 100G services alongside existing 10G DWDM traffic. Scope: OTU service interfaces and wavelength multiplexing; the published designs include optical amplification and dispersion compensation.

Cloud infrastructure operator · China
29 DWDM systems

Data center backbone across 14 OTM, 3 OADM and 12 OLA stations. 40-channel protected ring at 100G / 200G per wavelength; longest published route 1,116 km.

Municipal public security · Metro OTN
2×10GE per district

District bureaus connected to the city bureau over intersecting OTN rings with ring protection. Initial 2×10GE per district bureau, with capacity to expand each district to 200G.

Rural cooperative bank · China
26 branches

Ten WDM systems over a single fiber connect 26 branches across nine towns to headquarters. Each branch has its own optical channel for a dedicated GE line, physically isolated.

Manufacturing network · Guangzhou

DWDM and OTN equipment, built in Guangzhou.

WincoTek DWDM / OTN platforms, cards and optical-layer equipment are produced in our Guangzhou manufacturing network. Built in ISO 9001-certified manufacturing partners; CE, RoHS, FCC and TÜV test reports available per model on request.

3 yearsHardware warranty
1 yearSoftware warranty
WincoTek WTN8600-DCI4 platform

Send the route, span loss, existing channels and required services.

We reply with a candidate design, equipment list and validation plan for that link.

FAQ

DWDM / OTN questions.

Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.

What capacity can a WincoTek DWDM system carry?

Up to 800G per wave and 25.6 Tb/s per fiber pair, with 96 channels at 50 GHz on the WTN8600-DCI platforms.

Which platforms are available?

The WTN8600-DCI series (1U and 2U) for data center interconnect, and the WTNS8600 family of 1U to 5U WDM chassis, open line system and integrated point-to-point devices, from 1.25G to 400G per channel.

Can it reuse our existing fiber and equipment?

Yes. Upgrades are designed on installed fiber, starting from your route, span loss and service mix, and validated before cutover.

How are links protected and managed?

Optical line, multiplex-section and channel protection (OLP, OMSP, OCHP) switch in under 50 ms. Management is via SNMP and NETCONF / YANG.

How do we start a design?

Send one link for review: route length, span losses, fiber type and the services to carry. We return a design and bill of materials.