Passive opticsfor FTTx builds.
PLC splitters, patch cords and pigtails, MPO/MTP trunks, drop cable and distribution boxes for PON, ODN and FTTH networks, from the central office to the subscriber. Built to your split plan, connector and fiber specification.

One split plan, three packages.
Planar lightwave circuit splitters distribute optical power through a silica-based waveguide: compact, broadband, stable and highly uniform. They connect central-office and terminal equipment in PON, ODN and FTTx networks, and are designed to meet RoHS, GR-1209-CORE and GR-1221-CORE requirements.

Mini steel tube
For distribution points near the subscriber. Fast installation, minimal space; input and output pigtails connect directly.
- Fiber: G.657A standard, G.652D optional; 0.9 mm
- Pigtail: 0.5 / 1.0 / 1.5 / 2.0 m, customizable

ABS box
The splitter chip in a protective ABS module, with fanned-out, connectorized input and output fibers.
- Connectors: LC, SC, FC, ST; UPC or APC
- Example: 1×16, G.657A1, 0.9 mm, 1.5 m, SC/APC

LGX cassette
Plug-in LGX cassettes and 19-inch rack-mount units, with adapters on the front panel for clean patching.
- Formats: LGX cassette and 19-inch rack-mount
- Adapters: LC, SC, FC or ST; UPC or APC
Standard 1×N: 1×2, 1×3, 1×4, 1×5, 1×6, 1×7, 1×8, 1×9, 1×12, 1×16, 1×24, 1×32, 1×48 and 1×64; 1×128 and 2×N from 2×2 to 2×128 also available. Unequal ratios for cascaded designs: FBT 1×2 from 1/99 to 45/55, PLC 1×5 and 1×9 from 5/95 to 50/50.
Full specifications →Loss budgets you can design to.
Maximum values unless noted. Fiber G.657A or customer-specified; operating temperature −40 to +85 °C for every configuration.
1×N PLC splitter
| Parameter | Limit | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 |
|---|---|---|---|---|---|---|---|
| Operating wavelength | nm | 1260–1650 | 1260–1650 | 1260–1650 | 1260–1650 | 1260–1650 | 1260–1650 |
| Insertion loss, P grade | dB max | 3.8 | 7.1 | 10.2 | 13.5 | 16.5 | 20.2 |
| Uniformity | dB max | 0.4 | 0.6 | 0.8 | 1.2 | 1.5 | 2.0 |
| PDL | dB max | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.4 |
| Return loss | dB min | 55 | 55 | 55 | 55 | 55 | 55 |
| Directivity | dB min | 55 | 55 | 55 | 55 | 55 | 55 |
| WDL | dB max | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
| Temperature stability (−40 to +85 °C) | dB max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Mini module L×W×H | mm | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×4 | 80×20×6 | 100×40×6 |
| Cassette module L×W×H | mm | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 140×115×18 |
2×N PLC splitter
| Parameter | Limit | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
|---|---|---|---|---|---|---|---|
| Insertion loss | dB max | 4.2 | 7.6 | 10.5 | 13.8 | 17 | 20.8 |
| Uniformity | dB max | 0.9 | 1.1 | 1.2 | 1.5 | 1.8 | 2.2 |
| PDL | dB max | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 | 0.4 |
| Return loss / directivity | dB min | 55 | 55 | 55 | 55 | 55 | 55 |
| WDL | dB max | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
| Cassette module L×W×H | mm | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 140×115×18 |
Values exclude optical connector loss; add 0.3 dB for each connector in the optical path. Other ratios, including 1×3, 1×6, 1×12, 1×24, 1×48, 1×128 and 2×128, per datasheet at quotation.
Bend-insensitive, tested at every termination.
Patch cords for interconnect and cross-connect paths, linking incoming fiber to equipment and enabling flexible patching. G.657.A1 bend-insensitive fiber with a 10 mm minimum bend radius saves space in dense racks and is fully compatible with G.652 fiber.

Patch cords
Single-mode and multimode, simplex and duplex. Grade A precision zirconia ferrules for low loss, duplex clips for easy polarity management, PVC riser or LSZH jackets. Models include SM-DX-LC/UPC, SM-DX-SC/APC, SM-DX-FC/UPC and SM-DX-ST/APC.
Pigtails and armored cords
Single-mode SC/APC and LC/UPC pigtails and OM3 LC/UPC multimode pigtails for splice trays, ODF and closures.
- Armored patch cables: steel armor and aramid yarn strength member under the jacket for crush and rodent resistance, while staying flexible.
- Example code: SC/APC-SC/APC-G652D-3.0mm-PVC-3M-SM
- Data center: polarity-switchable uniboot duplex LC (A-to-A or A-to-B in the field) and high-density LC/MPO pull-tab cords.
| Option | Patch cords and pigtails |
|---|---|
| Connectors | SC, LC, FC, ST; simplex or duplex; UPC or APC polish |
| Fiber | Single-mode OS2: G.652D, G.657A1, G.657A2. Multimode: OM1, OM2, OM3, OM4, OM5 |
| Cable diameter | 0.9 / 2.0 / 3.0 mm |
| Jacket | PVC or LSZH |
| Length | 0.5 m, 1 m, 1.5 m, 2 m; customized lengths |
| Standards | Manufactured and tested to TIA-604 (FOCIS) and IEC 61754 |
| Applications | Data centers, telecom networks, enterprise LANs; 1G, 10G, 25G, 40G, 100G and 400G Ethernet |
Uniboot duplex LC and LC/MPO pull-tab patch cords
| Item | Single-mode | Multimode |
|---|---|---|
| Insertion loss | ≤0.30 dB | ≤0.30 dB |
| Return loss | ≥50 dB (PC); ≥60 dB (APC) | N/A |
| Durability | <0.20 dB typical change, 1000 matings | <0.20 dB typical change, 1000 matings |
| Operating temperature | −40 to +85 °C | −40 to +85 °C |
Pre-terminated trunks for 40G and 100G.
Pre-terminated trunks replace time-consuming field termination in high-density data centers and buildings. Extend them through plug-and-play cassettes or MTP/MPO panels for fast links between MDA, HDA and EDA areas, and for smooth 40G / 100G upgrades.

MTP/MPO trunk cable
Anti-compression and tensile reinforcement at both ends, precise custom lengths for trunk, extension and branch cables, and an optional pulling eye or tube for field installation.
Cassettes and distribution frames
- 96FO fixed MTP/MPO-LC cassette: branches a 12-core trunk to 24 LC or 12 SC adapters; metal housing; for HDF rack-mount ODF.
- 72FO sliding cassette: for 19-inch 1U–3U patch panels; LC or SC front, MPO rear; 12F and 24F LGX modules.
- Standards: TIA/EIA-604-D-2007 and IEC 61754-7:2008; selectable system polarity; bend-insensitive fiber.
- Fiber distribution frame: standard 19-inch cabinet, top or bottom entry, up to 792 fibers, SC / FC / LC / ST adapters, lockable door.
| Item | MTP/MPO trunk specification |
|---|---|
| Fiber count | 4 to 144 cores; 40G configuration 8 fibers, 100G configuration 20 fibers |
| Connectors | Pinned 8 / 12-fiber MTP at both ends, factory-installed, 100% performance-tested |
| Polarity | Methods A, B and C |
| Insertion loss, single-mode | Low-loss ≤0.35 dB; standard ≤0.7 dB |
| Insertion loss, multimode | Low-loss ≤0.35 dB; standard ≤0.5 dB |
| Return loss | ≥60 dB single-mode; ≥30 dB multimode |
| Durability | <0.2 dB typical change after 500 matings |
| Operating temperature | −40 to +85 °C |
| Flame rating / jacket | OFNR, OFNP and LSZH; PVC, LSZH and other jacket options |
MPO-LC cassette module insertion loss (max)
| Grade | Single-mode | Multimode |
|---|---|---|
| Standard | 1.0 dB | 1.0 dB |
| Low loss | 0.7 dB | 0.7 dB |
| Ultra-low loss | 0.5 dB | 0.35 dB |
The last span to the subscriber.
Self-supporting drop cable from the pole to the premises, and a 24-core distribution box where the feeder cable meets the drops.
FTTH drop cable
Self-supporting aerial FTTH drop fiber patch cable for outdoor and indoor runs.
| Item | Drop cable |
|---|---|
| Type | Self-supporting aerial FTTH drop fiber patch cable, outdoor / indoor |
| Cable diameter | 2.0 × 5.0 mm |
| Jacket | Low smoke zero halogen (LSZH); PVC optional |
| Fiber count | 1, 2 or 4 cores |
| Fiber | G.652D, G.657A1 or G.657A2 |
| Strength member | Steel wire or FRP messenger |
| Packing | 1, 2 or 4 km per reel |
24-core FTTH distribution box
Holds up to 24 subscribers. A termination point for the feeder cable to connect with drop cable, integrating fiber splicing, splitting, distribution, storage and cable connection in one solid protective box.
- Splicing: integrated splice cassette and cable management rods; fusion or mechanical splice
- Splitting: two 1×8 splitters can be installed as an option
- Drops: 24-port cable entrance for drop cable
- Fiber handling: fibers managed within a controlled bend radius; easy to maintain and extend capacity
- Other terminal boxes: 1×2 to 1×32 types, SC/APC or SC/UPC adapters, with splitters installed
Passive optics, built in Leizhou.
WincoTek splitters, patch cords and cable assemblies are produced in our Leizhou manufacturing network: a dedicated PLC splitter line, automated production cells, cleanroom assembly and microscopic end-face inspection, with every termination tested. Built in ISO 9001-certified manufacturing partners; CE, RoHS, FCC and TÜV test reports available per model on request.

Active access, supplied on request. OLT, ONU and BOSA active access equipment is supplied on request alongside your passive order, together with GPON OLT SFP modules from our transceiver range.
Supplied on request →Send the split plan, connector, fiber type, length and quantity.
We reply with matched configurations, datasheets and a sample plan.
FTTx questions.
Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.
Which PLC splitter ratios are available?
Standard 1×2 to 1×64, plus 1×128 and 2×N from 2×2 to 2×128. Unequal ratios are available for cascaded designs.
Which packages and connectors can we order?
Mini steel tube, ABS box, LGX cassette and 19-inch rack-mount, with LC, SC, FC or ST connectors in UPC or APC.
What is the operating temperature?
−40 to +85 °C for every splitter configuration, with temperature stability of 0.5 dB max.
Can you build to our split plan?
Yes. Send your FTTx bill of materials with split plan, connector and fiber specification, and we quote per line.
Optical network solutions