Home/Products/FTTx passives

Passive opticsfor FTTx builds.

PLC splitters, patch cords and pigtails, MPO/MTP trunks, drop cable and distribution boxes for PON, ODN and FTTH networks, from the central office to the subscriber. Built to your split plan, connector and fiber specification.

WincoTek PLC splitter in ABS box with SC connectors
Split ratios
1×2–1×64
Wavelength
1260–1650 nm
Return loss
≥55 dB
Operating
−40 to +85 °C
PLC splitters

One split plan, three packages.

Planar lightwave circuit splitters distribute optical power through a silica-based waveguide: compact, broadband, stable and highly uniform. They connect central-office and terminal equipment in PON, ODN and FTTx networks, and are designed to meet RoHS, GR-1209-CORE and GR-1221-CORE requirements.

WincoTek mini steel-tube PLC splitter with SC/APC connectors

Mini steel tube

For distribution points near the subscriber. Fast installation, minimal space; input and output pigtails connect directly.

  • Fiber: G.657A standard, G.652D optional; 0.9 mm
  • Pigtail: 0.5 / 1.0 / 1.5 / 2.0 m, customizable
WincoTek ABS box PLC splitter with SC/UPC connectors

ABS box

The splitter chip in a protective ABS module, with fanned-out, connectorized input and output fibers.

  • Connectors: LC, SC, FC, ST; UPC or APC
  • Example: 1×16, G.657A1, 0.9 mm, 1.5 m, SC/APC
WincoTek LGX cassette PLC splitter with SC/APC adapters

LGX cassette

Plug-in LGX cassettes and 19-inch rack-mount units, with adapters on the front panel for clean patching.

  • Formats: LGX cassette and 19-inch rack-mount
  • Adapters: LC, SC, FC or ST; UPC or APC

Standard 1×N: 1×2, 1×3, 1×4, 1×5, 1×6, 1×7, 1×8, 1×9, 1×12, 1×16, 1×24, 1×32, 1×48 and 1×64; 1×128 and 2×N from 2×2 to 2×128 also available. Unequal ratios for cascaded designs: FBT 1×2 from 1/99 to 45/55, PLC 1×5 and 1×9 from 5/95 to 50/50.

Full specifications →
Splitter specifications

Loss budgets you can design to.

Maximum values unless noted. Fiber G.657A or customer-specified; operating temperature −40 to +85 °C for every configuration.

1×N PLC splitter

ParameterLimit1×21×41×81×161×321×64
Operating wavelengthnm1260–16501260–16501260–16501260–16501260–16501260–1650
Insertion loss, P gradedB max3.87.110.213.516.520.2
UniformitydB max0.40.60.81.21.52.0
PDLdB max0.20.20.20.250.30.4
Return lossdB min555555555555
DirectivitydB min555555555555
WDLdB max0.50.50.50.80.81.0
Temperature stability (−40 to +85 °C)dB max0.50.50.50.50.50.5
Mini module L×W×Hmm60×7×460×7×460×7×460×12×480×20×6100×40×6
Cassette module L×W×Hmm100×80×10100×80×10100×80×10120×80×18120×80×18140×115×18

2×N PLC splitter

ParameterLimit2×22×42×82×162×322×64
Insertion lossdB max4.27.610.513.81720.8
UniformitydB max0.91.11.21.51.82.2
PDLdB max0.20.20.30.30.40.4
Return loss / directivitydB min555555555555
WDLdB max0.50.50.50.80.81.0
Cassette module L×W×Hmm100×80×10100×80×10100×80×10120×80×18120×80×18140×115×18

Values exclude optical connector loss; add 0.3 dB for each connector in the optical path. Other ratios, including 1×3, 1×6, 1×12, 1×24, 1×48, 1×128 and 2×128, per datasheet at quotation.

Patch cords & pigtails

Bend-insensitive, tested at every termination.

Patch cords for interconnect and cross-connect paths, linking incoming fiber to equipment and enabling flexible patching. G.657.A1 bend-insensitive fiber with a 10 mm minimum bend radius saves space in dense racks and is fully compatible with G.652 fiber.

WincoTek single-mode duplex LC to SC fiber patch cord

Patch cords

Single-mode and multimode, simplex and duplex. Grade A precision zirconia ferrules for low loss, duplex clips for easy polarity management, PVC riser or LSZH jackets. Models include SM-DX-LC/UPC, SM-DX-SC/APC, SM-DX-FC/UPC and SM-DX-ST/APC.

Pigtails and armored cords

Single-mode SC/APC and LC/UPC pigtails and OM3 LC/UPC multimode pigtails for splice trays, ODF and closures.

  • Armored patch cables: steel armor and aramid yarn strength member under the jacket for crush and rodent resistance, while staying flexible.
  • Example code: SC/APC-SC/APC-G652D-3.0mm-PVC-3M-SM
  • Data center: polarity-switchable uniboot duplex LC (A-to-A or A-to-B in the field) and high-density LC/MPO pull-tab cords.
OptionPatch cords and pigtails
ConnectorsSC, LC, FC, ST; simplex or duplex; UPC or APC polish
FiberSingle-mode OS2: G.652D, G.657A1, G.657A2. Multimode: OM1, OM2, OM3, OM4, OM5
Cable diameter0.9 / 2.0 / 3.0 mm
JacketPVC or LSZH
Length0.5 m, 1 m, 1.5 m, 2 m; customized lengths
StandardsManufactured and tested to TIA-604 (FOCIS) and IEC 61754
ApplicationsData centers, telecom networks, enterprise LANs; 1G, 10G, 25G, 40G, 100G and 400G Ethernet

Uniboot duplex LC and LC/MPO pull-tab patch cords

ItemSingle-modeMultimode
Insertion loss≤0.30 dB≤0.30 dB
Return loss≥50 dB (PC); ≥60 dB (APC)N/A
Durability<0.20 dB typical change, 1000 matings<0.20 dB typical change, 1000 matings
Operating temperature−40 to +85 °C−40 to +85 °C
MPO / MTP

Pre-terminated trunks for 40G and 100G.

Pre-terminated trunks replace time-consuming field termination in high-density data centers and buildings. Extend them through plug-and-play cassettes or MTP/MPO panels for fast links between MDA, HDA and EDA areas, and for smooth 40G / 100G upgrades.

WincoTek MTP/MPO pre-terminated trunk cable on reel

MTP/MPO trunk cable

Anti-compression and tensile reinforcement at both ends, precise custom lengths for trunk, extension and branch cables, and an optional pulling eye or tube for field installation.

Cassettes and distribution frames

  • 96FO fixed MTP/MPO-LC cassette: branches a 12-core trunk to 24 LC or 12 SC adapters; metal housing; for HDF rack-mount ODF.
  • 72FO sliding cassette: for 19-inch 1U–3U patch panels; LC or SC front, MPO rear; 12F and 24F LGX modules.
  • Standards: TIA/EIA-604-D-2007 and IEC 61754-7:2008; selectable system polarity; bend-insensitive fiber.
  • Fiber distribution frame: standard 19-inch cabinet, top or bottom entry, up to 792 fibers, SC / FC / LC / ST adapters, lockable door.
ItemMTP/MPO trunk specification
Fiber count4 to 144 cores; 40G configuration 8 fibers, 100G configuration 20 fibers
ConnectorsPinned 8 / 12-fiber MTP at both ends, factory-installed, 100% performance-tested
PolarityMethods A, B and C
Insertion loss, single-modeLow-loss ≤0.35 dB; standard ≤0.7 dB
Insertion loss, multimodeLow-loss ≤0.35 dB; standard ≤0.5 dB
Return loss≥60 dB single-mode; ≥30 dB multimode
Durability<0.2 dB typical change after 500 matings
Operating temperature−40 to +85 °C
Flame rating / jacketOFNR, OFNP and LSZH; PVC, LSZH and other jacket options

MPO-LC cassette module insertion loss (max)

GradeSingle-modeMultimode
Standard1.0 dB1.0 dB
Low loss0.7 dB0.7 dB
Ultra-low loss0.5 dB0.35 dB
Drop cable & distribution box

The last span to the subscriber.

Self-supporting drop cable from the pole to the premises, and a 24-core distribution box where the feeder cable meets the drops.

FTTH drop cable

Self-supporting aerial FTTH drop fiber patch cable for outdoor and indoor runs.

ItemDrop cable
TypeSelf-supporting aerial FTTH drop fiber patch cable, outdoor / indoor
Cable diameter2.0 × 5.0 mm
JacketLow smoke zero halogen (LSZH); PVC optional
Fiber count1, 2 or 4 cores
FiberG.652D, G.657A1 or G.657A2
Strength memberSteel wire or FRP messenger
Packing1, 2 or 4 km per reel

24-core FTTH distribution box

Holds up to 24 subscribers. A termination point for the feeder cable to connect with drop cable, integrating fiber splicing, splitting, distribution, storage and cable connection in one solid protective box.

  • Splicing: integrated splice cassette and cable management rods; fusion or mechanical splice
  • Splitting: two 1×8 splitters can be installed as an option
  • Drops: 24-port cable entrance for drop cable
  • Fiber handling: fibers managed within a controlled bend radius; easy to maintain and extend capacity
  • Other terminal boxes: 1×2 to 1×32 types, SC/APC or SC/UPC adapters, with splitters installed
Manufacturing network · Leizhou, Guangdong

Passive optics, built in Leizhou.

WincoTek splitters, patch cords and cable assemblies are produced in our Leizhou manufacturing network: a dedicated PLC splitter line, automated production cells, cleanroom assembly and microscopic end-face inspection, with every termination tested. Built in ISO 9001-certified manufacturing partners; CE, RoHS, FCC and TÜV test reports available per model on request.

3 yearsHardware warranty
100%Terminations tested
WincoTek LGX cassette PLC splitter

Active access, supplied on request. OLT, ONU and BOSA active access equipment is supplied on request alongside your passive order, together with GPON OLT SFP modules from our transceiver range.

Supplied on request →

Send the split plan, connector, fiber type, length and quantity.

We reply with matched configurations, datasheets and a sample plan.

FAQ

FTTx questions.

Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.

Which PLC splitter ratios are available?

Standard 1×2 to 1×64, plus 1×128 and 2×N from 2×2 to 2×128. Unequal ratios are available for cascaded designs.

Which packages and connectors can we order?

Mini steel tube, ABS box, LGX cassette and 19-inch rack-mount, with LC, SC, FC or ST connectors in UPC or APC.

What is the operating temperature?

−40 to +85 °C for every splitter configuration, with temperature stability of 0.5 dB max.

Can you build to our split plan?

Yes. Send your FTTx bill of materials with split plan, connector and fiber specification, and we quote per line.