Data centers,built and testedin a Schneider-audited factory.
Factory-integrated AIDC infrastructure from a single rack to multi-megawatt clusters. Power, cooling, racks and monitoring are integrated at our Hangzhou base, a Schneider Electric-audited supplier, and pass FAT before shipping. The site only lifts, connects and commissions.

Move the build off site. Keep the quality.
Conventional builds stack months of multi-trade work on site. We fabricate, integrate and test every module under factory control, and ship it ready to connect.
Integrated
Power distribution, cooling, IT racks, containment, fire protection and DCIM in one engineered system.
Tested
Incoming, in-process and system inspection, then factory acceptance testing before release.
Deployed
On site: placement, interconnection and commissioning. Containerized builds go live up to 60% faster than a traditional build.
Scaled
Start with one module and add capacity block by block; each module runs independently.
One rack to multi-megawatt.
The same building blocks repeat at every scale. Tell us the IT load and site, and we size the configuration.
LS Series server rack
42U / 47U12 models, 600 / 800 mm wide, 1,000–1,200 mm deep, 3,000 kg static and dynamic load. Details →
Warrior edge MDC
1 cabinetUPS 3–10 kVA, rack AC 3.5–8.1 kW, PDU, FM200 / Novec 1230, monitoring and access control in one enclosure. Details →
Wizard MDC
Up to 9 IT racks1+1 to 1+9 cabinet rows; UPS 10–30 kVA in N, N+1 or 2N; on-site installation in a day or less. Details →
WT-MMDC micro-modular
≤125 kW / moduleUp to 24 cabinets single aisle or 48 dual aisle; UPS 25–125 kVA, in-row AC 25–60 kW. Details →
AI POD overhead
≤250 kW / rack42–46 racks and 2.2–8.0 MW per pod; busway to 6,300 A; 5 MW liquid thermal capacity. Details →
WT-CDU rack CDU
30–150 kWFive models, 4U to 12U; N+N pumps, dual power feeds, leak detection, Modbus / TCP/IP. Details →
Containerized, air or liquid
100 kW to 10 MW+1.25 MW standard blocks, 10–150 kW+ per rack, UPS to 5,000 kVA+, −40 to +55 °C. Details →

Edge and micro data centers
Warrior and Wizard bring a complete computer room to bank branches, carrier business halls, campuses and edge nodes, without building a server room.

Micro-modular rows
WT-MMDC rows for telecom operators, enterprises and financial institutions. Seven units deliver 630 kW across 126 racks in Azerbaijan.

AI POD for accelerated compute
The overhead services that normally take months on site, prefabricated as one steel-framed pod and lifted into place.

Containerized liquid cooling
IT hall, electrical pod and cooling plant in factory-built container modules for AI and HPC, relocatable and outdoor-ready.
Key specifications
| Product | Scale | Rack density | Power | Cooling | Fire / monitoring |
|---|---|---|---|---|---|
| LS Series rack | 42U / 47U, 12 models | — | Dual vertical PDU slots | Mesh doors, >80% open | — |
| Warrior | 1 cabinet | To 8.1 kW | UPS 3 / 6 / 10 kVA, on-line | Rack AC 3.5 / 4.2 / 8.1 kW | FM200 / Novec 1230, web + email alerts |
| Wizard | 1+1 to 1+9 cabinets | By IT load | UPS 10–30 kVA; N, N+1, 2N | In-rack or in-row, contained aisle | Gas suppression, web + mobile DCIM |
| WT-MMDC | ≤24 / ≤48 cabinets | 2–5 kW in delivered sites | UPS 25–125 kVA, ≥96%; ≤125 kW / module | In-row AC 25–60 kW; DX or chilled water | FM-200, DCIM |
| AI POD | 42–46 racks, 2.2–8.0 MW | To 250 kW | Busway to 4,000 A (2Bus) / 6,300 A (4Bus), 600 V | TCS piping, DN250 header, 5 MW / pod | Modbus, BACnet, leak detection |
| WT-CDU | Y30 to Y150 | 30–150 kW / unit | 0.7–3 kW rated | Primary 35/45 °C; PG25 secondary | Modbus, TCP/IP, UDP |
| Containerized | 100 kW–10 MW+, 4–100+ racks | 10–150 kW+ | UPS 100–5,000 kVA+; N, N+1, 2N; Li-ion | Air, liquid or hybrid; −40 to +55 °C | FM200 / Novec 1230, BA + DCIM |
Actual values depend on project configuration. Full datasheets on request.
Four systems, engineered as one.
Supplied as standalone products or integrated into a complete AIDC module.
Power distribution
- Distribution panels
- Integrated UPS
- Intelligent busway
- Rack PDU and RPP
Cooling
- Precision and in-row AC
- CDU and manifolds
- Fan walls, dual-coil chilled water
- Air-cooled chillers, dry coolers
Racks & containment
- Server and liquid-cooling racks
- Cold and hot aisle containment
- Prefabricated overhead systems
- Cable management
Monitoring & safety
- DCIM platform and sensors
- Access control
- Gas fire suppression
- VESDA early detection
Air-cooled path
10–30 kW per rack, for enterprise, telecom and edge.
Liquid-cooled path
Cold-plate, dual-loop: 50–150 kW+ per rack at a lower PUE, for AI and HPC.
Liquid-cooled blocks, sized to the cluster.
Engineering examples from our design library. Every project is configured to its own load, redundancy and climate.
- 1× dual-40 ft module
- 6 liquid-cooled racks, 100 kW each
- 2N power, 10-minute Li-ion
- Chilled water + free cooling
- 18 liquid-cooled racks
- 2N redundancy for IT and chillers
- 10-minute Li-ion backup
- Phased expansion
- 5× dual-40 ft modules
- 30 liquid-cooled racks, 100 kW each
- 2N power, 10-minute Li-ion
- Magnetic-bearing chillers, Novec 1230 + VESDA
- 100 kW+ per rack
- 2N UPS, 10-minute Li-ion
- Magnetic-bearing or water chiller with free cooling
- Novec 1230 + VESDA
One process, definition to lifecycle.
Manufacturing builds the platform; integration turns it into an operating data center. After handover we support operations, spares and expansion.
Requirements
Load, racks, density, climate, power.
Engineering
Structure, electrical, HVAC, monitoring, fire drawings.
Manufacturing
Fabrication and assembly.
Integration
All disciplines connected.
FAT
Tested before release.
Deployment
Lift, connect, commission.
Lifecycle
Remote monitoring, spares, upgrades.
1.24 MW delivered in 5 countries.
Scope in each: layout design, power and cooling integration, factory build, FAT and delivery.
| Country | Type | IT capacity | Racks | Per rack | UPS | Cooling | Backup | Configuration |
|---|---|---|---|---|---|---|---|---|
| Kazakhstan | Air-cooled containerized | 168 kW | 24 | 7 kW | 2N | N+1 in-row | 20 min VRLA | 3× 40 ft units |
| Iraq | Air-cooled containerized | 120 kW | 20 | 6 kW | 2N | N+1 in-row | 2 h VRLA | 3× 40 ft units |
| Ethiopia | Air-cooled containerized | 40 kW | 8 | 5 kW | 2N | N+1 in-row | 60 min VRLA | 1× 40 ft module |
| Kazakhstan | Air-cooled containerized | 45 kW | 9 | 5 kW | N | N+1 in-row | 10 min VRLA | 3 modules, 15 kW each |
| Azerbaijan | Indoor micro-modular | 630 kW | 126 | 5 kW | 2N | N+1 in-row | 15 min Li-ion | 7× WT-MMDC |
| Brunei | Indoor micro-modular | 240 kW | 80 | 3 kW | 2N | N+1 in-row | 1 h VRLA | 5× WT-MMDC |
7.2 MW liquid-cooled containerized
6× 1.2 MW B200/B300 GPU cluster blocks: 12 IT PODs, 14 electrical PODs and 4 auxiliary PODs, 72 liquid racks, 2N for IT and chillers.
40 MW liquid-cooled containerized
16× 2.5 MW compute blocks at 50 kW per rack, N+1 power and N+1 cooling.
WT-MMDC for public safety and banking
Public safety: 3 units, 360 kW, 120 racks. Banking: 8 units, 224 kW, 112 racks; and 8 units, 300 kW, 150 racks. All 2N UPS, N+1 in-row cooling, FM-200.
Built at a Schneider-audited base in Hangzhou.
Modular, containerized, air and liquid-cooled systems are fabricated, integrated and tested at our Hangzhou manufacturing base, an audited supplier to Schneider Electric, with quality controlled from incoming inspection to final release.
Send IT load, rack count, kW per rack, climate and power supply.
We return a matched configuration with layout and lead time.
Data center questions.
Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.
What does factory-integrated mean?
Power distribution, cooling, IT racks, containment, fire protection and DCIM are integrated and tested in the factory, then pass FAT before shipping. On site the modules are placed, connected and commissioned.
What scale can you deliver?
From a single LS Series rack or Warrior edge cabinet to containerized campuses of 10 MW and more, built from 1.25 MW standard blocks.
Do you support liquid cooling for AI?
Yes. Rack CDUs from 30 to 150 kW, AI POD overhead systems rated up to 250 kW per rack, and containerized liquid-cooled data centers for AI and HPC.
Where have your data centers been delivered?
6 projects in 5 countries, 1.24 MW of IT capacity in total, including Azerbaijan and Brunei.
Where are they built?
At the Hangzhou base, a Schneider Electric-audited supplier with 48,000 m² of plant, building data center infrastructure since 2009.