Server racks andDCIM monitoring.
The LS Series is a heavy-duty 19-inch rack platform rated for 3,000 kg static and dynamic load, with seismic resistance, high-airflow mesh doors and structured cable management built in. A single monitoring platform watches power, cooling, environment and security across every system we build.

A rigid, well-ventilated home for critical IT.
High-grade steel with a ten-fold profile, generous cable channels, dual vertical PDU slots and hexagonal mesh doors keep dense installations tidy, powered and cool through moves, expansions and day-to-day operations.

Exploded view: frame, doors, side panels and roof.
Key advantages
- Ultra-high load capacity: Static & dynamic load rated at 3,000 kg
- Seismic-proven: Meets YD 5083-2005; intensity-8 earthquake resistance with ≥450 kg load
- Total compatibility: Dual vertical PDU slots plus large-capacity cable management
- Safe grounding: ≥2 grounding points at the base; 6 mm² flexible bonding wire between door and frame
- Easy lifting & moving: Pre-drilled eyebolt holes on top for crane or hoist handling
- Superior airflow: Hexagonal mesh doors in 1.2 mm steel, >80% ventilation rate
12 models: height, width, depth.
Select height (42U / 47U), width (600 / 800 mm) and depth (1000 / 1100 / 1200 mm) to match the installation. All dimensions in mm; packing volume in m³.
| Model | Capacity | Dimension (W × D × H) | Cable inlet | Packed (W × D × H) | Packing vol. |
|---|---|---|---|---|---|
| WT-LS61042 | 42U | 600 × 1000 × 2000 | 720 × 90 | 650 × 1050 × 2150 | 1.467 |
| WT-LS61142 | 42U | 600 × 1100 × 2000 | 750 × 90 | 650 × 1150 × 2150 | 1.607 |
| WT-LS61242 | 42U | 600 × 1200 × 2000 | 850 × 90 | 650 × 1250 × 2150 | 1.747 |
| WT-LS81042 | 42U | 800 × 1000 × 2000 | 720 × 90 | 850 × 1050 × 2150 | 1.919 |
| WT-LS81142 | 42U | 800 × 1100 × 2000 | 750 × 90 | 850 × 1150 × 2150 | 2.102 |
| WT-LS81242 | 42U | 800 × 1200 × 2000 | 850 × 90 | 850 × 1250 × 2150 | 2.284 |
| WT-LS61047 | 47U | 600 × 1000 × 2200 | 720 × 90 | 650 × 1050 × 2350 | 1.604 |
| WT-LS61147 | 47U | 600 × 1100 × 2200 | 750 × 90 | 650 × 1150 × 2350 | 1.757 |
| WT-LS61247 | 47U | 600 × 1200 × 2200 | 850 × 90 | 650 × 1250 × 2350 | 1.909 |
| WT-LS81047 | 47U | 800 × 1000 × 2200 | 720 × 90 | 850 × 1050 × 2350 | 2.097 |
| WT-LS81147 | 47U | 800 × 1100 × 2200 | 750 × 90 | 850 × 1150 × 2350 | 2.297 |
| WT-LS81247 | 47U | 800 × 1200 × 2200 | 850 × 90 | 850 × 1250 × 2350 | 2.497 |
Racks ship flat-packed for efficient logistics, or pre-assembled when the site needs them ready to roll in. Drawings and load calculations on request.
Structure, finish, doors and cabling.
Bolted SPCC / SGCC steel frame on an automated powder coating line, for a durable, scratch-resistant, uniform finish.
| Area | Item | Specification |
|---|---|---|
| Structure | Frame | Ten-fold profile, bolted assembly; ships flat-packed or pre-assembled |
| Thickness | Main frame ≥2.0 mm; mounting angles ≥1.5 mm; other parts ≥1.2 mm | |
| Material | High-grade SPCC / SGCC steel | |
| Finish | Process | Automated multi-stage powder coating line: pre-degreasing, main degreasing, spray wash, immersion treatment, spray wash and drying |
| Coating | Sand-texture powder 60–80 µm; wrinkle powder 80–110 µm | |
| Curing | 200 °C for 15–20 minutes | |
| Doors | Front / rear | Front door removable; rear door removable, split type with 4-point locking |
| Material / ventilation | 1.2 mm steel with hexagonal perforations; >80% open area | |
| Cable management | Top / bottom | 4 cable entry holes with brush strips on top; 2 cable entry holes at the bottom for underfloor cabling |
| Rear / front | 2 vertical cable management panels (standard); 2 finger-type cable trays (optional, 800 mm-wide racks only) | |
| Options | On request | Shelf, PDU (type and count customized), 2-inch wheels, cable management rings, horizontal cable brush, finger-type cable management |

Detail views: grounding points, cable brush, mounting rails and swing handle lock.
Every system, one view.
DCIM and sensors are integrated at the factory with power, cooling, racks and fire protection, then supported after handover with remote monitoring and alarm and incident assessment.

Facility view: live cooling and power schematic.

Module view: environment, energy and alarm list.
Sensors and access
- Temperature & humidity sensor: 9–15 VDC (rated 12 VDC); −20 °C to 80 °C; 0–100% RH; ±0.3 °C and ±3% RH at 25 °C
- RS485 interface, up to 256 nodes (64 recommended); Modbus / TCP-IP
- Point-type photoelectric water leakage detection; smoke sensor; door magnetic switch
- Access control: card / password, fingerprint or face optional
Values from the Warrior Series datasheet.
Lifecycle support
- Commissioning and remote monitoring
- Alarm and incident assessment
- Troubleshooting coordination
- Maintenance and critical spare parts planning
- System upgrades and future capacity expansion
From one cabinet to a campus.
The monitoring scope grows with the system it watches.
| System | Interface | What is monitored |
|---|---|---|
| Single cabinet · Warrior | Door touch screen (VTU2.0 / VTU3.0), web platform, email alarm | Temperature & humidity, PDU, UPS, cooling, door access, water leakage, smoke |
| Cabinet row · Wizard | Web browser and mobile client; multiple modules managed centrally on one platform | Temperature & humidity, airflow, power load, equipment health; real-time alerts, predictive maintenance |
| Module · WT-MMDC | Integrated DCIM platform | Power, cooling, environmental conditions and security systems |
| Facility · Containerized | BA + DCIM; remote access and multi-site management | UPS, batteries and distribution; CDU, pumps, valves and coolant; temperature, humidity and air quality; access control and CCTV |
| Liquid cooling · AI POD / WT-CDU | Modbus, BACnet, TCP, PLC (AI POD); Modbus, TCP/IP, UDP (WT-CDU) | Pressure, flow, temperature and leak detection; integration with existing DCIM and BMS |
Ideal for every IT environment.
Modern data centers, enterprise IT facilities, telecom rooms, cloud infrastructure and edge computing sites.
Enterprise data centers
Rigid, ventilated racks for servers, storage and network equipment.
Colocation facilities
Standard 42U / 47U footprints in 600 and 800 mm widths.
Telecom infrastructure
Seismic resistance to intensity 8 under YD 5083-2005.
Cloud computing
Dual vertical PDU slots and large-capacity cable management.
AI computing clusters
3,000 kg static and dynamic load rating for dense installations.
Edge data centers
Ships flat-packed or pre-assembled, ready to roll in.
Racks and monitoring in every delivered system.
IT racks, containment and DCIM are integrated into each containerized and micro-modular system we deliver: 1.24 MW in 5 countries.
7× WT-MMDC, 630 kW, 5 kW per rack.
5× WT-MMDC, 240 kW, 3 kW per rack, energy & petrochemical.
3× 40 ft units, 168 kW, 7 kW per rack.
3× 40 ft units, 120 kW, 6 kW per rack.
1× 40 ft module, 40 kW, 5 kW per rack.
3 modules, 15 kW each, 5 kW per rack.
The same building blocks, at every scale.
Every system is integrated and tested at our Hangzhou manufacturing base, an audited supplier to Schneider Electric. Data center overview →
Containerized & liquid-cooled
IT hall, power and cooling plant in factory-built container modules, 100 kW to 10 MW+.
View →Data centerMicro-modular & edge
Warrior, Wizard and WT-MMDC: one cabinet to 48-cabinet modules.
View →Data centerAI POD & liquid cooling (CDU)
Prefabricated overhead pods to 250 kW per rack; rack CDUs from 30 to 150 kW.
View →Send IT load, rack count, kW per rack, climate and power supply.
We return a matched configuration with layout and lead time.