Micro-modular and edgedata centers.
A complete computer room, from one cabinet to a 48-cabinet module. IT racks, UPS, precision cooling, power distribution, containment, fire protection and monitoring are pre-integrated at the factory for plug-and-play deployment.

Three formats, one way of working.
Every unit is designed, integrated and tested before it leaves the factory, then installed and commissioned on site. No separate power room, cooling plant or monitoring build-out to coordinate.

Warrior
UPS 3–10 kVA · AC 3.5–8.1 kWUPS and batteries, precision cooling, power distribution, monitoring, fire suppression and access control in one enclosure. Deployment time cut by up to 70%.
Warrior specifications →
Wizard
1+1 to 1+9 · UPS 10–30 kVAOne integrated power and cooling cabinet plus up to nine IT racks, with enclosed aisle containment. On-site installation in ≤1 day.
Wizard specifications →
WT-MMDC
≤24 / ≤48 cabinets · UPS 25–125 kVASingle or double channel modules with in-row cooling, smart power distribution and DCIM. Deployment time reduced by up to 50%.
WT-MMDC specifications →At a glance
| Product | Format | Power | Cooling | Fire / monitoring |
|---|---|---|---|---|
| Warrior | 1 cabinet, 600/800 mm wide | UPS 3 / 6 / 10 kVA, on-line | Rack AC 3.5 / 4.2 / 8.1 kW | FM200 / Novec 1230; touch screen, web, email alerts |
| Wizard | 1+1 to 1+9 cabinets, 42U / 47U | UPS 10–30 kVA; N, N+1, 2N | Rack-mounted or in-row, contained aisle | Gas suppression; web and mobile monitoring |
| WT-MMDC | ≤24 cabinets single, ≤48 double channel | UPS 25–125 kVA, ≥96%; ≤125 kW / module | In-row AC 25–60 kW; DX, chilled or cooling water | FM-200 & intelligent detection; DCIM |
Micro-modular rows, fully contained.
IT racks, UPS, precision cooling, intelligent power distribution, containment, fire protection, security access and monitoring in one unified architecture, for rapid deployment and scalable expansion.
| Item | Specification |
|---|---|
| Model | WT-MMDC-S (single channel) / WT-MMDC-D (double channel) |
| Micro module: dimensions, single channel | With aisle containment: L × 2,200 × 2,300 mm, L × 2,200 × 2,400 mm, L × 2,400 × 2,300 mm, L × 2,400 × 2,400 mm |
| Micro module: dimensions, double channel | With aisle containment: L × 3,200 × 2,300 mm, L × 3,200 × 2,400 mm, L × 3,600 × 2,300 mm, L × 3,600 × 2,400 mm |
| Micro module: cabinets | Single channel ≤ 24 cabinets; dual channel ≤ 48 cabinets |
| Micro module: power supply | 208/380/400/415 V DC/AC, 50/60 Hz, 3 Ph + N + PE |
| Micro module: max IT load | 125 kW per module (with integrated UPS) / 145 kW (with integrated PDU) |
| Micro module: cabling and installation | Cable routing top or bottom; installation on raised floor |
| Cabinet enclosure | 2,000/2,200 mm × 600/800 mm × 1,200/1,100 mm (H × W × D); 42U / 47U; IP20 |
| Air conditioner | In-row or vertical direction of one end; DX, chilled water, or cooling water system |
| In-row air conditioner | Cooling capacity 25 kW, 35 kW, 40 kW, 50 kW, 60 kW; H 2,000 mm 2,000 mm × 300/600 mm × D;times; W 300/600 mm, depth per model; 208–415 V AC, 50/60 Hz, 3 Ph + N + PE; R410A, R407C |
| Integrated UPS | Rated capacity 25 kVA – 125 kVA; efficiency ≥ 96%; input 208/380/400/415 V AC, MCCB 250 A / 400 A; input PF full load > 0.99, half load > 0.98; output PF 0.9 / 1.0 |
| Integrated UPS: outputs | IT: 40 A / 1P × 24 × 2; A/C: 40 A or 63 A / 3P × 8; lighting: 10 A / 1P × 3 |
| Integrated power distribution cabinet | Input 380/400/415 V AC; MCCB IT 160 A / 250 A, A/C 160 A / 250 A; outputs IT 32 A / 1P, 40 A / 1P, 63 A / 1P, 32 A / 3P; A/C 40 A or 63 A / 3P |
| Precision power distribution cabinet | Input 208/380/400/415 V AC; MCCB 160 A / 250 A / 400 A; output 32 A / 1P, max 144 routes |
| Smart busbar | Input 208/380/400/415 V AC; MCCB 160 A / 250 A; output 32 A / 1P, 40 A / 1P, 63 A / 1P, 32 A / 3P |
Specifications are subject to project configuration.

Integrated DCIM: power, cooling, environmental conditions and security.
Hot aisle containment
Separates hot and cold air streams, maximizing cooling efficiency and reducing operational cost.
- Improved cooling efficiency
- Reduced energy consumption
- Stable equipment operating temperature
- Support for high-density computing
A small data hall that grows by the rack.
One integrated power cabinet (UPS, distribution and cooling) plus IT racks. Start with what the site needs today and add racks as demand grows. It connects directly to the building power supply, with N, N+1 or 2N redundancy.
Row configurations
| Configuration | Total | Typical use |
|---|---|---|
| 1+1 | 2 cabinets | Single-rack edge node with full power / cooling backup |
| 1+2 | 3 cabinets | Small branch or retail hub |
| 1+3 | 4 cabinets | Campus or business-hall deployment |
| 1+4 | 5 cabinets | Mid-size enterprise room replacement |
| 1+5 / 1+6 | 6–7 cabinets | Growing regional edge site |
| Up to 1+9 | 10 cabinets | Maximum row configuration |
Single UPS path
The economical baseline for standard edge sites.
Parallel modules
One redundant unit covers a failed module without dropping the load.
Two power paths
Dual utility / generator feeds, ATS and UPS: no single point of failure.
On-site install
Pre-integrated, plug-and-play; 100% of rack space left for IT.
Technical specifications
| Parameter | Specification |
|---|---|
| Enclosure | 42U / 47U; 600/800 × 2000/2200 × 1200/1400 mm (W × H × D) |
| Cabinet door | Polycarbonate door; front and rear door thickness ≥1.2 mm; side door ≥1.5 mm |
| Ground connection | More than two ground points reserved; BVR 6 mm² |
| Air conditioner | Rack-mounted or in-row; cooling capacity determined according to equipment power |
| Emergency exhaust | One draught fan per enclosure, air volume 239–288 CFM |
| UPS | 10 kVA to 30 kVA, rack-mounted, on-line; single-in single-out or three-in single-out |
| Power backup | Lead-acid batteries or lithium battery, 7Ah / 9Ah |
| PDM | Max 100A, 3-phase; 440 (W) × 12U (H) × 600 (D) mm; mains and UPS circuits; up to 51P air switches |
| Fire suppression | Gas fire trace tube (optional); local light and sound warning, sent to the monitoring room or control center |
| Monitoring, standard | Temperature & humidity sensor, door magnetic switch, smoke sensor, web monitoring |
| Monitoring, optional | 10-inch touch screen, SMS alerts, mobile app, liquid sensor, camera, access control (fingerprint, card swipe or password) |
| Package, per cabinet | 734/934 × 2200/2400 × 1368/1568 mm (W × H × D); 210–280 kg (no battery pack) |
The whole computer room, in one cabinet.
Power, cooling, monitoring, fire suppression and security in a single standardized enclosure, pre-installed and pre-tested at the factory. Deploys in days instead of months and is monitored centrally from day one.
| Parameter | Specification |
|---|---|
| Enclosure | Standard 19 in / 21 in; 600/800 × 2000/2200 × 1200/1400 mm (W × H × D) |
| Doors | Polycarbonate front door ≥6 mm; mesh rear door (one or two, optional) ≥1.2 mm; side door ≥1.2 mm |
| Precision cooling | Rack-mounted air conditioner, capacity 3.5 kW / 4.2 kW / 8.1 kW |
| Emergency exhaust | One draught fan, air volume 239–288 CFM |
| UPS | 3 kVA / 6 kVA / 10 kVA, rack-mounted with LCD screen; on-line, power factor ≥0.9 |
| Battery pack | Lead-acid battery, 8 × 12V 7Ah / 9Ah |
| PDM | 220V 32A / 63A input; 410 (W) × 4U (H) × 600 (D) mm; UPS input with bypass and surge protection; 22P MCB max |
| PDU | Smart / basic; 32A input, 12× C13 and 4× C19 outputs (customized) |
| Fire suppression | Rack-mounted gas unit, FM200 / Novec 1230; local alarm light and smoke sensor; email notification to administrator |
| Monitoring | Touch screen VTU2.0 / VTU3.0; email alarm, temperature & humidity, smoke sensor and web monitoring as standard; point-type photoelectric water leakage detection |
| Access control | Card / password standard; fingerprint / face optional |
Built for distributed sites.
Where a traditional server room cannot go, or is not worth building.
Telecom operators
Carrier business halls, 5G and edge network sites, edge and regional data centers.
Banking & finance
Bank branches and financial service sites; reliable infrastructure for critical services.
Enterprise
Headquarters, branch offices and mid-size enterprise room replacement.
Retail
Smart store infrastructure, local data processing and network management.
Education & campus
Campus networks and campus IT infrastructure.
Industrial edge & cloud
Smart manufacturing, edge nodes for cloud providers and healthcare facilities.
WT-MMDC in service.
Air-cooled micro-modular deployments, 20 kW – 100 kW per unit, all with 2N UPS and N+1 in-row cooling.
| Country | Vertical | IT capacity | Racks | Per rack | UPS | Cooling | Backup | Configuration |
|---|---|---|---|---|---|---|---|---|
| Azerbaijan | — | 630 kW | 126 | 5 kW | 2N | N+1 in-row | 15 min Li-ion | 7× WT-MMDC |
| Brunei | Energy & petrochemical | 240 kW | 80 | 3 kW | 2N | N+1 in-row | 1 h VRLA | 5× WT-MMDC |
| China | Public safety | 360 kW | 120 | 3 kW | 2N | N+1 in-row | 2 h VRLA | 3× WT-MMDC |
| China | Banking & finance | 224 kW | 112 | 2 kW | 2N | N+1 in-row | 2 h VRLA | 8× WT-MMDC |
| China | Banking & finance | 300 kW | 150 | 2 kW | 2N | N+1 in-row | 1 h VRLA | 8× WT-MMDC |
Fire safety in all listed projects: FM-200 & intelligent detection.

WT-MMDC rows installed on site.
Scope in each project
Layout design, power and cooling integration, factory build, FAT and delivery. On site: installation and commissioning, followed by operation support.
The same building blocks, at every scale.
Every system is integrated and tested at our Hangzhou manufacturing base, an audited supplier to Schneider Electric. Data center overview →
Containerized & liquid-cooled
IT hall, power and cooling plant in factory-built container modules, 100 kW to 10 MW+.
View →Data centerAI POD & liquid cooling (CDU)
Prefabricated overhead pods to 250 kW per rack; rack CDUs from 30 to 150 kW.
View →Data centerRacks & DCIM
LS Series 42U / 47U server racks and the monitoring platform across every system.
View →Send IT load, rack count, kW per rack, climate and power supply.
We return a matched configuration with layout and lead time.