What “pre-terminated” covers in an ODN
The optical distribution network is everything passive between the OLT port in the central office and the ONU at the subscriber: feeder fiber, splitters, distribution points, drop cables and patch cords. In a pre-terminated design each of these pieces is built and connectorized in the factory. A PLC splitter comes in an ABS box or cassette with fanned-out, connectorized fibers. The distribution box arrives with splice cassette, adapters and optional splitters fitted. Drop cables come as connectorized patch cables in fixed lengths. In the central office or a data center, pre-terminated MPO trunks replace field termination of high-count cables.
Splicing does not disappear completely. Feeder cables are often still spliced at the cabinet or in closures. The aim is to move the repetitive work, the hundreds of drops and distribution joints, from the street to the factory.
Plan the split before anything else
A GPON or XGS-PON port feeds many subscribers through passive splitters: 1:32 and 1:64 are common, 1:128 is possible. You can split once (centralized) or in two stages (cascaded, for example 1:4 at the cabinet and 1:8 at the distribution box). Cascaded designs place splitters closer to homes and reduce feeder fiber; unequal splitters help when one branch is much longer than the others.
The split ratio drives the loss budget more than anything else. From the WincoTek PLC splitter table, maximum insertion loss for P-grade splitters is 16.5 dB for 1×32 and 20.2 dB for 1×64, and the table adds 0.3 dB for each connector in the optical path. Two cascaded stages add up to roughly the same loss as one splitter with the same total ratio, plus the extra connectors between them.
Work the loss budget: a worked example
The method is the same for any optic: add fiber, splitter, connector and splice losses, keep at least 3 dB of margin, and check the result against the transmitter power and receiver sensitivity of the optics at both ends. The upstream direction (ONU to OLT, at 1310 nm) is usually the tighter one, because the ONU transmits less power and fiber loss is higher at 1310 nm than at 1490 nm.
Example with WincoTek optics: an ONU stick launching at least 0.5 dBm upstream and a class C+++ GPON OLT optic with a −30 dBm receiver give 30.5 dB of upstream budget.
| Upstream loss item | 1:32, 20 km | 1:64, 20 km | 1:64, 13 km |
|---|---|---|---|
| Feeder and drop fiber at 1310 nm (about 0.42 dB/km on G.652) | 8.4 dB | 8.4 dB | 5.5 dB |
| PLC splitter, P grade, max. | 16.5 dB | 20.2 dB | 20.2 dB |
| Six connectors at 0.3 dB | 1.8 dB | 1.8 dB | 1.8 dB |
| System margin | 3.0 dB | 3.0 dB | 3.0 dB |
| Total, against 30.5 dB budget | 29.7 dB: fits | 33.4 dB: does not fit | 30.5 dB: at the limit |
Splices are not included; add your splice count times the splice loss your crews achieve. The example shows why the split ratio and feeder length must be fixed together: at 1:64 the same optics reach only about 13 km. A higher-class OLT optic, a shorter feeder or fewer connectors restore the margin. Check the other end of the window too: a subscriber close to the OLT on a small split can overload the receiver, so look at the minimum loss as well as the maximum.
Connectors and end faces
PON networks generally use angled (APC) connectors, which reflect far less light back into the fiber than flat PC or UPC end faces. The rule is simple: APC mates only with APC. Mating an APC connector to a PC or UPC one through an adapter damages both end faces, and the damage stays after you unplug. PC to UPC works only as a temporary fix, with poorer return loss.
Specify both the connector and the end face on every line of the order, for example "SC/APC to SC/APC", not just "SC to SC". Check the equipment too: some subscriber devices have SC/PC receptacles, which need a hybrid cord rather than an APC drop plugged in directly.
Ask for insertion loss in numbers, not "low loss". Most connector loss comes from core misalignment inside the ferrule, measured in fractions of a micron. Better ferrule concentricity and tuning bring typical loss from about 0.2 dB down toward 0.1 dB per mated pair, and over a dozen connections that difference shows up in the budget.
MPO trunks on the central-office side
Where the ODN starts, in the central office or a co-located data hall, high-count MPO trunks and cassettes connect OLT racks to the outside plant. Three things must match on every MPO channel: fiber count, pin type (male to female) and polarity. TIA-568 defines three polarity types: Type A (straight through, key up to key down), Type B (full crossover, key up to key up) and Type C (pairs crossed). Choose one method for the whole channel before ordering, and confirm whether the trunk is APC or PC.
Lengths, slack and documentation
Pre-terminated cables cannot be cut to length, so the site survey is the critical step. Measure each route, add slack for routing and future moves, and standardize on a few lengths where you can. Label both ends of every cord with its port and keep the as-built split plan; it is the map you will use for every repair.
Test and accept
Factory-terminated parts arrive tested, but the installed link still needs an acceptance test. The simplest check uses a light source and power meter: the loss is the source reading minus the meter reading at the far end. Compare each branch with the planned budget and record the result. Optical time-domain testing adds the location of each event if a branch is out of limits.
Choose the optics after the ODN
OLT optics come in classes. Higher classes transmit more power and receive weaker signals, at a higher module cost. Pick the class from the split ratio and reach you designed, not from the highest number on the label. WincoTek offers GPON OLT SFP modules from class B+ to C+++, an XGS-PON OLT N1 SFP+ and a GPON / EPON ONU stick, alongside the splitters, patch cords, drop cable, distribution boxes and MPO trunks for the ODN. Send us your split plan, connector and fiber specification, lengths and quantities, and we quote per line.
Optical network solutions