WincoTek 800G OSFP 2xDR4 500 m Transceiver(WTOS800-2DR4-500C)
WTOS800-2DR4-500C is an 800G OSFP transceiver that runs two 400G DR4 interfaces over single-mode fiber up to 500 m. Eight 53.125 GBd PAM4 lanes at 1310 nm leave through two MPO-12 APC receptacles, with EML transmitters and PIN receivers. It supports Ethernet and InfiniBand NDR, and breaks out to eight 100G DR links in AI and data center fabrics.

800G OSFP 2xDR4 at a glance.
Main optical, electrical and environmental values for WTOS800-2DR4-500C.
| Parameter | Value |
|---|---|
| Ordering code | WTOS800-2DR4-500C: OSFP 800 Gb/s 2×DR4 500 m transceiver, 0 to 70 °C |
| Data rate | 850 Gb/s aggregate; 8 × 53.125 GBd PAM4 lanes |
| Standards | IEEE 802.3cu 8×100GBASE-DR optical; IEEE 802.3ck 8×100GAUI-1 C2M electrical; IBTA 1.6 InfiniBand NDR; OSFP MSA Rev 5.0; CMIS Rev 5.0 |
| Wavelength | 1304.5 to 1317.5 nm (1311 nm typ.), each lane |
| Laser / receiver | EML transmitter, PIN photodiode receiver |
| TX power, each lane (avg.) | −2.9 to 4.0 dBm; OMAouter −0.8 to 4.2 dBm |
| RX sensitivity (OMAouter), each lane | Max(−3.9, SECQ − 5.3) dBm; stressed sensitivity −1.9 dBm |
| RX average receive power, each lane | −5.9 to 4 dBm; damage threshold 5 dBm |
| Operating distance | 2 m to 500 m on single-mode fiber |
| Connector | Dual MPO-12 with APC end-face |
| Power | <16.5 W; 2 W max. in low power mode |
| Supply | 3.135 to 3.465 V |
| Case temperature | 0 to 70 °C |
| DDM | Yes: temperature, voltage, TX bias, TX and RX power per lane |
Main values for WTOS800-2DR4-500C. Full WincoTek datasheet: DatasheetPDF
Where it is used.
From the datasheet application list and common network use.
- 800G Ethernet spine and leaf links up to 500 m on single-mode fiber
- Breakout to 8 × 100G DR server or switch ports
- Two independent 400G DR4 links from one OSFP cage
- InfiniBand NDR clusters for AI training and HPC
Planning a 2xDR4 link.
What to check before ordering optics and cabling.
In a leaf-spine fabric every leaf connects to every spine, so each uplink needs an optic at both ends. One 2xDR4 module serves two 400G DR4 links, or eight 100G DR ports through breakout cabling, which keeps spine port counts down as the fabric grows.
The two MPO-12 receptacles are angle-polished (APC). An APC connector will not mate correctly with a flat PC one, so order trunks and breakout cords with APC ends, and confirm fiber count, pin type (male or female) and key orientation before you order.
The far end must match lane for lane: another 2xDR4 port, two 400G DR4 ports or eight 100G DR ports. Check the host port supports the power class of an OSFP 800G module.
Related WincoTek models.
800G OSFP options. 2xDR4 is the single-mode choice up to 500 m; SR8 runs on multimode. Further 800G types are listed on the transceivers page, datasheet on request.
| Model | Type | Fiber / reach | Wavelength | Connector | Max. power |
|---|---|---|---|---|---|
| WTOS800-2DR4-500C this page DatasheetPDF | 800G 2×DR4 (8×100G DR breakout) | SMF, 500 m | 1310 nm | 2× MPO-12 (APC) | <16.5 W |
| WTOS800-SR8-100C DatasheetPDF | 800G SR8 | MMF, 60 m OM3 / 100 m OM4 | 850 nm | 2× MPO-12 / MPO-16 (APC) | <14 W |
| WTOS800-SR8-50C DatasheetPDF | 800G SR8 | MMF, 30 m OM3 / 50 m OM4 | 850 nm | 2× MPO-12 (APC) | <17 W |
| WTOS400-DR4-500C-CM DatasheetPDF | 400G OSFP DR4 | SMF, 500 m | 1310 nm | MPO-12 (APC) | <10 W |
Full range and all datasheets: optical transceivers.
Coded to your host, tested first.
Host vendor names describe the target platform only.
Coding & compatibility
WTOS800-2DR4-500C is coded for the host platform you name, for example Cisco, Juniper, Huawei, Arista, Nokia switches and routers. We read and back up the module data, write the approved profile, then read back and verify it with DDM. Compatibility is validated per host model and software release, so we recommend testing coded samples on your equipment before a volume order.
Quality & warranty
Built in ISO 9001-certified manufacturing partners. CE, RoHS, FCC and TÜV test reports are available for each model on request.
Warranty: hardware 3 years, software 1 year.
Questions on this model.
Not answered here? Email waley@wincoteknetwork.com or message us on WhatsApp.
Can WTOS800-2DR4-500C break out to 100G?
Yes. The datasheet lists 8 × 100GbE breakout as an application. Each of the eight lanes runs as a 100G DR link, reached through MPO-12 APC to duplex LC breakout cabling.
Does it support InfiniBand?
Yes. The datasheet states support for both Ethernet and InfiniBand NDR, with compliance to IBTA specification 1.6.
Which cabling does it need?
Single-mode fiber with two MPO-12 connectors with APC (angled) end-faces. Use APC MPO trunks or APC breakout cords; flat PC connectors will not mate correctly.
What power and temperature apply?
Under 16.5 W, with 2 W maximum in low power mode, and a 0 to 70 °C case temperature. Check the OSFP port power class on your host.
Can WTOS800-2DR4-500C be coded for our switches?
Yes. WTOS800-2DR4-500C is coded for the host platform you name, then read back and verified. Compatibility is validated per host model and software release, so test coded samples before a volume order.
Request a quote for WTOS800-2DR4-500C.
Send the host model and software release, quantity and coding needs. We reply with a matched P/N and sample plan.
Email waley@wincoteknetwork.com · WhatsApp / phone +86 176 8896 6828
Optical network solutions